Comprehensive environmental test box for car lights

  • Hot Line:18322499311

車(chē)燈綜合環(huán)境試驗(yàn)箱.jpg

Performance indicators and system composition of the comprehensive environment test box (fog test box) for car lights


model


GC-YW-8000


Volume and size


Nominal internal volume


About 8m 3


Effective size of inner box


 


Left area: 1200mm × 2500mm × 2000mm (W × D × H)


Right area: 800mm × 2500mm × 1000mm (W × D × H)


Exterior space


Approximately 2500 × 5300 × 2800mm (D length × W width × H height) including sloping roof height


weight


About 2200kg


Bottom load-bearing capacity of the machine


The bottom plate strengthens the load-bearing capacity of the studio, with an average load-bearing capacity of 2 tons per square meter,


A 1mm thick anti slip and corrosion-resistant hard plastic silicone is laid at the bottom of the laboratory, which is resistant to High temperatures


Drainage holes are installed on the bottom plate of the laboratory


Work noise


≤ 70db, measured at a distance of 1.2 meters from the ground and 1 meter in front of the machine


maximum power


70KW


Maximum current


108A


 


Power supply conditions


And power supply


AC 380V three-phase four wire+protective grounding; The allowable voltage fluctuation range is ± 10% V;


The allowable frequency fluctuation range is 50 ± 0.5HZ; TN-S power supply or TT power supply


The grounding resistance of the protective grounding wire is less than 4 Ω


Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must independently control the use of the equipment


performance index 


Environmental conditions for use


1. The ambient temperature is 5-30 ℃ and the relative humidity is ≤ 85% R.H;


2. The installation site must be a flat and vibration free ground;


3. The equipment should be kept away from heat sources and flammable and explosive substances;


4. The installation location should not be directly exposed to sunlight and maintain indoor air circulation;


5. The equipment installation site needs to be clean and cannot be installed in dusty areas or dust outlets


Temperature performance


Laboratory temperature range: Temperature range: -30 ℃ to+100 ℃ (left and right zones)


Temperature resolution: 0.01 ℃


Temperature fluctuation: ≤ ±0.5℃


Temperature deviation: ≤ ±2.0℃


Temperature uniformity: ≤ ±2℃


Temperature change rate


Heating rate: ≥ 3 ℃/min (average empty load throughout the left and right zones)


Cooling rate: ≥ 2 ℃/min (average empty load throughout the left and right zones)


Humidity performance


Humidity range: 10% to 98% R.H (left and right zones)


Temperature resolution: 0.1%


Humidity fluctuation: ≤ ±3%RH


Humidity deviation: ≤ ±3%RH


Humidity uniformity (no light, no wind speed): ≥ At 75% RH: humidity uniformity ≤ ± 3% RH


When the humidity is ≤ 75% RH: humidity uniformity is ≤ ± 5% RH


Main technical parameters


 


Spray volume (m1/80cm2/h) 1.0~2.0 (collect at least 16 hours and take the average value)


Spray pressure: 1.00 ± 0.01kgf/cm2


PH value: neutral 6.5~7.2 acidic 3.0~3.3


Spray, static time: 1min~9999H fixed value operation can be set arbitrarily, and the program running time can be set to cycle operation


Spray system (left area)


6 sets of nozzle type nozzles, nozzle material SUS # 304; Pressure ranging from 1 to 3kg/cm 2;


Flow rate: adjustable from 6-21L/min, can cover the entire surface of the car lights;


Spray water temperature control: 8 ℃~30 ℃, accuracy ± 2 ℃;


Spray conditions: Meet Q/JLY J7110231D-2022, maintain water temperature at 15 ℃± 3 ℃, rain parameters at a pressure of 3bar, flow rate of 18L/min, and spray continuously for 30 minutes.


Lighting system (left area)


Radiation intensity of 800w/m 2~1120w/m 2 @ 20 ℃~60 ℃, 10%~70% (air temperature and humidity range under lighting state);


Spectral matching degree: Class B (according to the AM1.5 standard solar spectral specification);


Spectral stability: ≤ 5% (according to AM1.5 standard solar spectral specifications);


Illumination angle: Rotate the Z-axis by 30 degrees and rotate the X-axis outward by 45 degrees


Wind speed system


Wind speed range: The wind speed can be adjusted to 15m/s, using a multi blade fan wind speed generating device


Timing range: 1min to 999h (divided into stages)


Wind speed regulation: The variable frequency controller is used to control the wind speed output, and the controller detects the wind speed value and provides feedback


Anemometer: Digital Wind Speed Detector


Wind speed direction: horizontal direction


Wind speed range: 5-15m/s adjustable (left zone)


Wind speed range: 2-5m/s adjustable (right zone)


Wind speed control: Variable frequency control, speed adjustment, wind speed and anemometer detection


Test standards


5.10 Mist Verification Test in Q/JLY J7110231D-2022


GMW14906 (Lamp Development and Validation Test Procedure)


JA3710-FG (Technical Specifications for External Lighting and Signal Devices of Passenger Cars)


QJGAC 1250.028-2020 Technical Conditions for Front Combination Lamps


Verification standards for fog by various vehicle manufacturers


Structural method


Split design, the equipment is divided into five design systems: box section (left testing area, right testing area), cabinet (refrigeration section and electrical control system), controller system, ice water machine, etc


Left testing area: 1200mm × 2500mm × 2000mm (W × D × H), the left area of the test chamber is the lens installation surface (external components), and tests such as lighting, constant temperature and humidity, cold water rainfall (spray), and wind speed system are carried out according to standards in this area


Right testing area: 800mm × 2500mm × 1000mm (W × D × H), the right area of the testing chamber is the back of the installed lamp (engine room surface), which can be used for high and low temperature cycling and constant temperature and humidity testing


Laboratory door


Left compartment door: front fully open single wing additional glass observation window with double-layer silicone rubber seal and door lock, convenient for personnel to enter the compartment for operation


Right area box door: Double door, 2000mm length on both sides, placement and installation of car lights, with 2 sets of glass observation windows attached


Observation window: Four layer vacuum glass insulated window, with additional 13W lighting for observing the test sample. The left window has a blackout curtain


Sample placement


The sample placement holes in the left and right areas are 2100 * 750mm (W * H), which can accommodate up to 2000mm of car lights. They are sealed with high-temperature resistant and flame-retardant soft cloth


A set of lamp fixture racks in the right area, made of SUS304 # stainless steel, with U-shaped screw fixing holes for easy fixation of lamp fixtures


Humidity system


Humidification water circuit: adopts a dual-purpose device of automatic water inlet and drawer type water tank water supply, with manual switching between water circulation recovery or non recovery


Humidification: Steam humidification


Dehumidification: Condensation dehumidification method


Structural features:


Laboratory structure


 


Outer wall material: SUS304 stainless steel plate, stainless steel thickness 1.2mm


Inner wall material: SUS316 stainless steel plate, stainless steel thickness 1.2mm


Bottom plate material: high-quality anti slip SUS316 stainless steel with a thickness of 3.0mm


Spray control system (reference, meets performance requirements)


Spray nozzle SUS304 # material wide angle nozzle with large coverage area, quantity 6 sets


Spray water pump adjusts water flow rate from 6 liters to 21 L/min


The spray flow rate is detected by an electronic flowmeter


Water temperature control adopts ice water machine water circulation temperature control of 8 ℃~30 ℃


Spray water circulation, spray water circulation, filter impurities, and automatic drainage pipeline design


The sprinkler water tank is made of SUS304 # stainless steel with a capacity of 150L. It is equipped with an additional circulating water inlet and outlet, as well as a water replenishment port, drainage port, and overflow port


Lighting control system (reference, meets performance requirements)


The lighting power supply adopts 2 sets of high stability 4KW lighting power supplies, and adjusts the output of the lamp tube to 50% to 100%


The light source adopts two sets of 4000W metal halide lamps


Spectral range 280nm to 3000nm


Simulated full spectrum irradiation intensity of sunlight, adjustable from 800 to 1120W/m


The irradiation angle is equipped with a built-in stainless steel lamp holder that can move forward and backward, and the rotation angle of the lamp source can be adjusted by 30 ° to 80 °


The irradiation sensor adopts a low-temperature resistant full spectrum irradiation intensity meter, with a temperature resistance of -40 to 150 ℃


Safety protection device


Power protection, residual current circuit breaker safety protection, under reverse phase sequence protection


Emergency switch, emergency stop switch protection device


Overcurrent protection overload: overcurrent (overload) protection devices for electric heating, motors, compressors, etc


Fault abnormality protection: When a fault abnormality occurs, cut off the control power supply, indicate the cause of the fault, and output an alarm signal


Insulation layer


Fire resistant high-strength PU polyurethane foam insulation material (more heat-resistant and fire-resistant than general PU), insulation coefficient: less than 0.0212kcal/m2hr

Box door


Double opening walk-in box door, double opening door structure, each door is 2500mm wide and 5500mm high, with doors set in the length direction.


Box door locking device and built-in anti reverse locking device


Door opening size: width 5000mm * height 5500mm;


The material of the laboratory box door is the same as that of the storage board;


The laboratory is equipped with built-in lighting fixtures located at the top of the laboratory


 


 


 


 


 


 


 


Observation window


1. 2 observation windows: There are 2 (including side single doors) conductive film explosion-proof and anti fog tempered glass observation windows with dimensions of W600 * H800mm on the door; Simultaneously equipped with conductive film explosion-proof, anti fog, and anti frost tempered glass observation windows, specially customized.


Install one conductive film explosion-proof and anti fog tempered glass observation window on the side, with glass sizes of W400 * H600mm in sequence


The above observation windows are all equipped with contraction curtains or louvers


control panel


Power indicator, spray indicator, demist indicator, cleaning button


Temperature controller, main power switch, spray switch, demist switch


Distribution control cabinet


Water filling solenoid valve, spray solenoid valve, demisting solenoid valve, distribution board, cooling fan


Overtemperature protector, air saturation pressure tank, spray control valve, saline water supply pump device


heating system 


A water ditch is set up at the bottom of the laboratory, and heating pipes are installed inside the ditch, using steam heating method and titanium alloy heating pipes, P. I. D Control Heating to Achieve Temperature Balance


Heating bucket anti-corrosion treatment


Efficient nickel alloy material+PTFE surface treatment electric heater; Adopting external electric steam humidification (stainless steel armored heater); The inner surface of the humidification bucket has been treated with Teflon spray coating to prevent the formation of rust and scale at welding points;


Humidification system 


The humidifier is equipped with a real-time dynamic water pump to meet the needs of humidification and maintaining humidity inside the box; Equipped with professional dual stage water filters to meet the anti scaling treatment requirements during the circulation of humidification water.


Dehumidification system


Condensation dehumidification; Using a professional evaporation pressure regulating device can ensure long-term humidity operation of the equipment and prevent frost formation on the evaporator; The condensed water after dehumidification can flow out through the drainage hole at the bottom of the experimental area.


test room


Water replenishment system


Fully automatic water replenishment control system, simply connect to the tap water pipe for automatic control, easy to use


 


Liquid Water Replenishment System


1. Liquid medicine water supply device: a large water tank made of PVC, with a hidden water storage capacity of about 3m3 inside


2. Method of supplementing medication; The corrosion-resistant film pump is used to lift the stored liquid medicine to the bottom of the spray tower for spray


drainage system


A 2-inch drainage outlet is installed at the bottom behind the laboratory, with a drainage valve control device and manual drainage method. The drainage location is specified by the customer (if the underground sewer is not made of metal, it can be directly discharged into the underground sewer)


Spray system


The Bernoulli principle is used to extract salt water and then atomize it uniformly. The temperature of the salt water atomization pool is consistent with that of the laboratory, ensuring no blocking crystallization phenomenon and ensuring the accuracy and standardization of the experiment

No blocking crystallization phenomenon can ensure the standard of continuous testing


The nozzle is made of special glass


Salt water level control: The salt water atomization pool uses a PP float switch to control the salt water level, and is equipped with a complete cover to prevent salt water droplets from falling back into the salt water atomization pool in the testing room


Spray mode


Continuous/gap type


Spray volume


The digital automatic display of the spray amount of saline water in the controller and the formation of the spray amount curve can effectively save the hourly data of the spray amount of saline water.


Air supply system


The spray pressure is adjusted to 1kg/cm2 in two stages. For the first time, the compressed air is adjusted to 2kg/cm2 to enter the saturated barrel for heating, and for the second time, the spray pressure is adjusted to 1kg/cm2


Fog exhaust system


1. Fully automatic pressure balanced fog exhaust device, simply connect the fog exhaust pipe, and automatically exhaust fog according to the pressure inside the box


2. The laboratory is equipped with 3 smoke exhaust holes with a diameter of ф 100mm. The smoke exhaust position is specified by the customer, and the extension pipe should not exceed 3 meters. If the extension exceeds 3 meters.


3. Optional salt spray filter with a salt spray processing capacity of 10m3/h;


Cleaning method


Spray devices are installed on both sides and the top of the laboratory. When the experiment is completed or the cleaning button is clicked, the laboratory can be cleaned. The cleaning time is up or the cleaning button can be turned off.


Cleaning water supply, using tap water supply method, with electromagnetic valve control for cleaning


Water supply system


1. The laboratory, saturation pressure tank, and cleaning water supply are automatically supplied with tap water


2. The preparation of test solution and saline solution should be based on dissolving 5 ± 1 units of sodium chloride in 95 units of water, and the water quality should meet the following requirements: maximum conductivity (μ S/cm @ 25 ℃) 5; Minimum resistivity (M Ω. cm @ 25 ℃) 0.2; PH value 6.5-7.2; Careful attention should be paid to the chemical composition of salt. The salt used should be sodium chloride, and the total amount of impurities should not exceed 0.3%. The content of halides (bromides, fluorides, and iodides) composed of substances other than chlorides shall not exceed 0.1% of the salt content. The copper content should not exceed 0.3 ppm. Sodium chloride containing added anti caking agents should not be used, as the additive acts like a corrosion inhibitor. The maximum limits for these impurities are listed in Table 1. When the buyer and seller agree, they may request analysis based on the content limits of elements or compounds other than the chemical composition specified above. (Purified water, deionized water machine, or distilled water machine should be used for preparing the medicine)


Stable control system


The environmental chamber can work continuously for more than 100000 hours, and there is a pressure relief hole above to maintain positive indoor pressure in any state.


electric control system 


controller


The independently developed LCD display and capacitive touch screen temperature controller are mainly used to control laboratory temperature, pressure tank temperature, display relative humidity, salt water sedimentation, spray time and other information. They are easy to operate, sensitive, and have high display accuracy.


Temperature input mode


Human computer interface, touch input


Program capacity and control function


Available program quantity: up to 120 groups, one program can be combined from 1 to 99 segments


Usable memory capacity: 1200 segments, can execute commands repeatedly: each command can be executed up to 999 times, program slope can be set by the timeline, programs can be linked and used, and program creation adopts conversational operation with simple operation


Equipped with functions such as editing, clearing, and inserting, with 4 sets of time signal output control (controllable control of the ON/OFF action of the test object)


It has 9 sets of PID parameter settings, with jump and hold functions during program execution, and can display curves and obtain data; Date and time adjustment function; Button and screen lock (LOCK) function, can be connected to a computer for use


communication


RS-232 communication interface, can be used as a monitoring and remote control system, record test data


Operation mode


Program mode/fixed value mode


Setting method


Chinese/English interface, touch input


Set Range


Maximum temperature range with upper and lower limits of 5 ℃


Display resolution


Temperature: 0.01 ℃; Time: 1min;


Power off memory function


The power-off recovery mode can be set to: hot start/cold start/stop


Appointment startup function


You can freely set the startup time, and the machine will automatically run after turning on the power


Temperature measurement body


PT100 platinum resistor


 


Curve recording function


RAM with battery protection, capable of storing device settings, sampling values, and sampling time; The maximum recording time is 60 days (when the sampling period is 1.5 minutes)


Software usage environment


IBM PC compatible machine, with a P Ⅱ or above CPU, 128MB or above memory, Simplified Chinese Windows 2000 or Simplified Chinese Windows XP operating system


Temperature control method


Anti integral saturation PID, BTC balance temperature control method (temperature testing equipment)


Safety protection device


Test box


Extreme over temperature protection, water shortage protection


Saturated bucket


Extreme over temperature protection, water shortage protection


Saltwater supply system


Pump overload and water shortage protection


heating system 


Heating tube dry burning, abnormal water supply, abnormal drainage


Power Supply


Leakage protection, overload and short circuit protection


Storage environment requirements


The ambient temperature of the equipment should be maintained within 0 ℃ to+45 ℃


Installation site requirements


The distance between the left, right, and rear wall panels of the test chamber and the wall must not be less than 600mm, and the distance between the front and the wall must not be less than 800mm. When transporting equipment, whether it is possible to enter the entrance, passage, elevator, etc., to avoid affecting the progress of your company's project.