Performance indicators and system composition of the comprehensive environment test box (fog test box) for car lights
model
GC-YW-8000
Volume and size
Nominal internal volume
About 8m 3
Effective size of inner box
Left area: 1200mm × 2500mm × 2000mm (W × D × H)
Right area: 800mm × 2500mm × 1000mm (W × D × H)
Exterior space
Approximately 2500 × 5300 × 2800mm (D length × W width × H height) including sloping roof height
weight
About 2200kg
Bottom load-bearing capacity of the machine
The bottom plate strengthens the load-bearing capacity of the studio, with an average load-bearing capacity of 2 tons per square meter,
A 1mm thick anti slip and corrosion-resistant hard plastic silicone is laid at the bottom of the laboratory, which is resistant to High temperatures
Drainage holes are installed on the bottom plate of the laboratory
Work noise
≤ 70db, measured at a distance of 1.2 meters from the ground and 1 meter in front of the machine
maximum power
70KW
Maximum current
108A
Power supply conditions
And power supply
AC 380V three-phase four wire+protective grounding; The allowable voltage fluctuation range is ± 10% V;
The allowable frequency fluctuation range is 50 ± 0.5HZ; TN-S power supply or TT power supply
The grounding resistance of the protective grounding wire is less than 4 Ω
Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must independently control the use of the equipment
performance index
Environmental conditions for use
1. The ambient temperature is 5-30 ℃ and the relative humidity is ≤ 85% R.H;
2. The installation site must be a flat and vibration free ground;
3. The equipment should be kept away from heat sources and flammable and explosive substances;
4. The installation location should not be directly exposed to sunlight and maintain indoor air circulation;
5. The equipment installation site needs to be clean and cannot be installed in dusty areas or dust outlets
Temperature performance
Laboratory temperature range: Temperature range: -30 ℃ to+100 ℃ (left and right zones)
Temperature resolution: 0.01 ℃
Temperature fluctuation: ≤ ±0.5℃
Temperature deviation: ≤ ±2.0℃
Temperature uniformity: ≤ ±2℃
Temperature change rate
Heating rate: ≥ 3 ℃/min (average empty load throughout the left and right zones)
Cooling rate: ≥ 2 ℃/min (average empty load throughout the left and right zones)
Humidity performance
Humidity range: 10% to 98% R.H (left and right zones)
Temperature resolution: 0.1%
Humidity fluctuation: ≤ ±3%RH
Humidity deviation: ≤ ±3%RH
Humidity uniformity (no light, no wind speed): ≥ At 75% RH: humidity uniformity ≤ ± 3% RH
When the humidity is ≤ 75% RH: humidity uniformity is ≤ ± 5% RH
Main technical parameters
Spray volume (m1/80cm2/h) 1.0~2.0 (collect at least 16 hours and take the average value)
Spray pressure: 1.00 ± 0.01kgf/cm2
PH value: neutral 6.5~7.2 acidic 3.0~3.3
Spray, static time: 1min~9999H fixed value operation can be set arbitrarily, and the program running time can be set to cycle operation
Spray system (left area)
6 sets of nozzle type nozzles, nozzle material SUS # 304; Pressure ranging from 1 to 3kg/cm 2;
Flow rate: adjustable from 6-21L/min, can cover the entire surface of the car lights;
Spray water temperature control: 8 ℃~30 ℃, accuracy ± 2 ℃;
Spray conditions: Meet Q/JLY J7110231D-2022, maintain water temperature at 15 ℃± 3 ℃, rain parameters at a pressure of 3bar, flow rate of 18L/min, and spray continuously for 30 minutes.
Lighting system (left area)
Radiation intensity of 800w/m 2~1120w/m 2 @ 20 ℃~60 ℃, 10%~70% (air temperature and humidity range under lighting state);
Spectral matching degree: Class B (according to the AM1.5 standard solar spectral specification);
Spectral stability: ≤ 5% (according to AM1.5 standard solar spectral specifications);
Illumination angle: Rotate the Z-axis by 30 degrees and rotate the X-axis outward by 45 degrees
Wind speed system
Wind speed range: The wind speed can be adjusted to 15m/s, using a multi blade fan wind speed generating device
Timing range: 1min to 999h (divided into stages)
Wind speed regulation: The variable frequency controller is used to control the wind speed output, and the controller detects the wind speed value and provides feedback
Anemometer: Digital Wind Speed Detector
Wind speed direction: horizontal direction
Wind speed range: 5-15m/s adjustable (left zone)
Wind speed range: 2-5m/s adjustable (right zone)
Wind speed control: Variable frequency control, speed adjustment, wind speed and anemometer detection
Test standards
5.10 Mist Verification Test in Q/JLY J7110231D-2022
GMW14906 (Lamp Development and Validation Test Procedure)
JA3710-FG (Technical Specifications for External Lighting and Signal Devices of Passenger Cars)
QJGAC 1250.028-2020 Technical Conditions for Front Combination Lamps
Verification standards for fog by various vehicle manufacturers
Structural method
Split design, the equipment is divided into five design systems: box section (left testing area, right testing area), cabinet (refrigeration section and electrical control system), controller system, ice water machine, etc
Left testing area: 1200mm × 2500mm × 2000mm (W × D × H), the left area of the test chamber is the lens installation surface (external components), and tests such as lighting, constant temperature and humidity, cold water rainfall (spray), and wind speed system are carried out according to standards in this area
Right testing area: 800mm × 2500mm × 1000mm (W × D × H), the right area of the testing chamber is the back of the installed lamp (engine room surface), which can be used for high and low temperature cycling and constant temperature and humidity testing
Laboratory door
Left compartment door: front fully open single wing additional glass observation window with double-layer silicone rubber seal and door lock, convenient for personnel to enter the compartment for operation
Right area box door: Double door, 2000mm length on both sides, placement and installation of car lights, with 2 sets of glass observation windows attached
Observation window: Four layer vacuum glass insulated window, with additional 13W lighting for observing the test sample. The left window has a blackout curtain
Sample placement
The sample placement holes in the left and right areas are 2100 * 750mm (W * H), which can accommodate up to 2000mm of car lights. They are sealed with high-temperature resistant and flame-retardant soft cloth
A set of lamp fixture racks in the right area, made of SUS304 # stainless steel, with U-shaped screw fixing holes for easy fixation of lamp fixtures
Humidity system
Humidification water circuit: adopts a dual-purpose device of automatic water inlet and drawer type water tank water supply, with manual switching between water circulation recovery or non recovery
Humidification: Steam humidification
Dehumidification: Condensation dehumidification method
Structural features:
Laboratory structure
Outer wall material: SUS304 stainless steel plate, stainless steel thickness 1.2mm
Inner wall material: SUS316 stainless steel plate, stainless steel thickness 1.2mm
Bottom plate material: high-quality anti slip SUS316 stainless steel with a thickness of 3.0mm
Spray control system (reference, meets performance requirements)
Spray nozzle SUS304 # material wide angle nozzle with large coverage area, quantity 6 sets
Spray water pump adjusts water flow rate from 6 liters to 21 L/min
The spray flow rate is detected by an electronic flowmeter
Water temperature control adopts ice water machine water circulation temperature control of 8 ℃~30 ℃
Spray water circulation, spray water circulation, filter impurities, and automatic drainage pipeline design
The sprinkler water tank is made of SUS304 # stainless steel with a capacity of 150L. It is equipped with an additional circulating water inlet and outlet, as well as a water replenishment port, drainage port, and overflow port
Lighting control system (reference, meets performance requirements)
The lighting power supply adopts 2 sets of high stability 4KW lighting power supplies, and adjusts the output of the lamp tube to 50% to 100%
The light source adopts two sets of 4000W metal halide lamps
Spectral range 280nm to 3000nm
Simulated full spectrum irradiation intensity of sunlight, adjustable from 800 to 1120W/m
The irradiation angle is equipped with a built-in stainless steel lamp holder that can move forward and backward, and the rotation angle of the lamp source can be adjusted by 30 ° to 80 °
The irradiation sensor adopts a low-temperature resistant full spectrum irradiation intensity meter, with a temperature resistance of -40 to 150 ℃
Safety protection device
Power protection, residual current circuit breaker safety protection, under reverse phase sequence protection
Emergency switch, emergency stop switch protection device
Overcurrent protection overload: overcurrent (overload) protection devices for electric heating, motors, compressors, etc
Fault abnormality protection: When a fault abnormality occurs, cut off the control power supply, indicate the cause of the fault, and output an alarm signal
Insulation layer
Fire resistant high-strength PU polyurethane foam insulation material (more heat-resistant and fire-resistant than general PU), insulation coefficient: less than 0.0212kcal/m2hr
Box door
Double opening walk-in box door, double opening door structure, each door is 2500mm wide and 5500mm high, with doors set in the length direction.
Box door locking device and built-in anti reverse locking device
Door opening size: width 5000mm * height 5500mm;
The material of the laboratory box door is the same as that of the storage board;
The laboratory is equipped with built-in lighting fixtures located at the top of the laboratory
Observation window
1. 2 observation windows: There are 2 (including side single doors) conductive film explosion-proof and anti fog tempered glass observation windows with dimensions of W600 * H800mm on the door; Simultaneously equipped with conductive film explosion-proof, anti fog, and anti frost tempered glass observation windows, specially customized.
Install one conductive film explosion-proof and anti fog tempered glass observation window on the side, with glass sizes of W400 * H600mm in sequence
The above observation windows are all equipped with contraction curtains or louvers
control panel
Power indicator, spray indicator, demist indicator, cleaning button
Temperature controller, main power switch, spray switch, demist switch
Distribution control cabinet
Water filling solenoid valve, spray solenoid valve, demisting solenoid valve, distribution board, cooling fan
Overtemperature protector, air saturation pressure tank, spray control valve, saline water supply pump device
heating system
A water ditch is set up at the bottom of the laboratory, and heating pipes are installed inside the ditch, using steam heating method and titanium alloy heating pipes, P. I. D Control Heating to Achieve Temperature Balance
Heating bucket anti-corrosion treatment
Efficient nickel alloy material+PTFE surface treatment electric heater; Adopting external electric steam humidification (stainless steel armored heater); The inner surface of the humidification bucket has been treated with Teflon spray coating to prevent the formation of rust and scale at welding points;
Humidification system
The humidifier is equipped with a real-time dynamic water pump to meet the needs of humidification and maintaining humidity inside the box; Equipped with professional dual stage water filters to meet the anti scaling treatment requirements during the circulation of humidification water.
Dehumidification system
Condensation dehumidification; Using a professional evaporation pressure regulating device can ensure long-term humidity operation of the equipment and prevent frost formation on the evaporator; The condensed water after dehumidification can flow out through the drainage hole at the bottom of the experimental area.
test room
Water replenishment system
Fully automatic water replenishment control system, simply connect to the tap water pipe for automatic control, easy to use
Liquid Water Replenishment System
1. Liquid medicine water supply device: a large water tank made of PVC, with a hidden water storage capacity of about 3m3 inside
2. Method of supplementing medication; The corrosion-resistant film pump is used to lift the stored liquid medicine to the bottom of the spray tower for spray
drainage system
A 2-inch drainage outlet is installed at the bottom behind the laboratory, with a drainage valve control device and manual drainage method. The drainage location is specified by the customer (if the underground sewer is not made of metal, it can be directly discharged into the underground sewer)
Spray system
The Bernoulli principle is used to extract salt water and then atomize it uniformly. The temperature of the salt water atomization pool is consistent with that of the laboratory, ensuring no blocking crystallization phenomenon and ensuring the accuracy and standardization of the experiment
No blocking crystallization phenomenon can ensure the standard of continuous testing
The nozzle is made of special glass
Salt water level control: The salt water atomization pool uses a PP float switch to control the salt water level, and is equipped with a complete cover to prevent salt water droplets from falling back into the salt water atomization pool in the testing room
Spray mode
Continuous/gap type
Spray volume
The digital automatic display of the spray amount of saline water in the controller and the formation of the spray amount curve can effectively save the hourly data of the spray amount of saline water.
Air supply system
The spray pressure is adjusted to 1kg/cm2 in two stages. For the first time, the compressed air is adjusted to 2kg/cm2 to enter the saturated barrel for heating, and for the second time, the spray pressure is adjusted to 1kg/cm2
Fog exhaust system
1. Fully automatic pressure balanced fog exhaust device, simply connect the fog exhaust pipe, and automatically exhaust fog according to the pressure inside the box
2. The laboratory is equipped with 3 smoke exhaust holes with a diameter of ф 100mm. The smoke exhaust position is specified by the customer, and the extension pipe should not exceed 3 meters. If the extension exceeds 3 meters.
3. Optional salt spray filter with a salt spray processing capacity of 10m3/h;
Cleaning method
Spray devices are installed on both sides and the top of the laboratory. When the experiment is completed or the cleaning button is clicked, the laboratory can be cleaned. The cleaning time is up or the cleaning button can be turned off.
Cleaning water supply, using tap water supply method, with electromagnetic valve control for cleaning
Water supply system
1. The laboratory, saturation pressure tank, and cleaning water supply are automatically supplied with tap water
2. The preparation of test solution and saline solution should be based on dissolving 5 ± 1 units of sodium chloride in 95 units of water, and the water quality should meet the following requirements: maximum conductivity (μ S/cm @ 25 ℃) 5; Minimum resistivity (M Ω. cm @ 25 ℃) 0.2; PH value 6.5-7.2; Careful attention should be paid to the chemical composition of salt. The salt used should be sodium chloride, and the total amount of impurities should not exceed 0.3%. The content of halides (bromides, fluorides, and iodides) composed of substances other than chlorides shall not exceed 0.1% of the salt content. The copper content should not exceed 0.3 ppm. Sodium chloride containing added anti caking agents should not be used, as the additive acts like a corrosion inhibitor. The maximum limits for these impurities are listed in Table 1. When the buyer and seller agree, they may request analysis based on the content limits of elements or compounds other than the chemical composition specified above. (Purified water, deionized water machine, or distilled water machine should be used for preparing the medicine)
Stable control system
The environmental chamber can work continuously for more than 100000 hours, and there is a pressure relief hole above to maintain positive indoor pressure in any state.
electric control system
controller
The independently developed LCD display and capacitive touch screen temperature controller are mainly used to control laboratory temperature, pressure tank temperature, display relative humidity, salt water sedimentation, spray time and other information. They are easy to operate, sensitive, and have high display accuracy.
Temperature input mode
Human computer interface, touch input
Program capacity and control function
Available program quantity: up to 120 groups, one program can be combined from 1 to 99 segments
Usable memory capacity: 1200 segments, can execute commands repeatedly: each command can be executed up to 999 times, program slope can be set by the timeline, programs can be linked and used, and program creation adopts conversational operation with simple operation
Equipped with functions such as editing, clearing, and inserting, with 4 sets of time signal output control (controllable control of the ON/OFF action of the test object)
It has 9 sets of PID parameter settings, with jump and hold functions during program execution, and can display curves and obtain data; Date and time adjustment function; Button and screen lock (LOCK) function, can be connected to a computer for use
communication
RS-232 communication interface, can be used as a monitoring and remote control system, record test data
Operation mode
Program mode/fixed value mode
Setting method
Chinese/English interface, touch input
Set Range
Maximum temperature range with upper and lower limits of 5 ℃
Display resolution
Temperature: 0.01 ℃; Time: 1min;
Power off memory function
The power-off recovery mode can be set to: hot start/cold start/stop
Appointment startup function
You can freely set the startup time, and the machine will automatically run after turning on the power
Temperature measurement body
PT100 platinum resistor
Curve recording function
RAM with battery protection, capable of storing device settings, sampling values, and sampling time; The maximum recording time is 60 days (when the sampling period is 1.5 minutes)
Software usage environment
IBM PC compatible machine, with a P Ⅱ or above CPU, 128MB or above memory, Simplified Chinese Windows 2000 or Simplified Chinese Windows XP operating system
Temperature control method
Anti integral saturation PID, BTC balance temperature control method (temperature testing equipment)
Safety protection device
Test box
Extreme over temperature protection, water shortage protection
Saturated bucket
Extreme over temperature protection, water shortage protection
Saltwater supply system
Pump overload and water shortage protection
heating system
Heating tube dry burning, abnormal water supply, abnormal drainage
Power Supply
Leakage protection, overload and short circuit protection
Storage environment requirements
The ambient temperature of the equipment should be maintained within 0 ℃ to+45 ℃
Installation site requirements
The distance between the left, right, and rear wall panels of the test chamber and the wall must not be less than 600mm, and the distance between the front and the wall must not be less than 800mm. When transporting equipment, whether it is possible to enter the entrance, passage, elevator, etc., to avoid affecting the progress of your company's project.