1.1 Product Overview
The aircraft engine dynamometer test room can be used to determine the adaptability of electronic products, components, materials, etc. for use and storage under low humidity, temperature cycling, and other conditions.
This laboratory adopts a relatively reasonable structure and stable and reliable control method, making it aesthetically pleasing,
Easy to operate, safe, and with High humidity control accuracy, it is an ideal equipment for conducting high and low temperature inspections.
1.2 Product Advantages and Technical Features
1.2.1 Utilize a multi-channel, environmentally friendly and energy-saving (low-noise) mechanical compression refrigeration system.
All materials, parts, components, raw materials, etc. of the device, whether domestically produced or imported, are made of environmentally friendly products;
According to the characteristics of mechanical compression refrigeration, a two-stage multi-channel main and bypass system is adopted, and the multi-channel main and bypass can be customized according to different requirements
Adaptive selection and activation of working conditions are enabled, and the entire control is automatically implemented by the intelligent control system according to the working conditions, changing
The traditional method of using a thermostat to control the heater to offset the cooling capacity is used to control the cooling capacity. Thereby achieving the effect of energy conservation,
Not only does energy consumption account for only 80% of similar products. It also reduces the operating load of the refrigeration compressor, minimizes equipment vibration, and
Noise, improve control accuracy. In order to achieve better energy-saving effects, frequency conversion technology is adopted to make the refrigeration compressor more efficient
The refrigeration output adapts to various temperature change rate requirements in the laboratory, while controlling the power loss during use to achieve energy-saving efficiency
Fruit. Use sound-absorbing and silencing methods at different locations throughout the structure and mechanical operation process to reduce overall equipment noise
Sound.
1.2.2. Independently developed multi-channel and multi-stage throttling system (refrigeration system).
The refrigeration system of this equipment is designed with different capillary main and bypass circuits based on different operating conditions, controlled by intelligent communication
The system automatically controls and adjusts the capillary throttling system according to the working conditions, ensuring that the flow rate can be adjusted, achieving
The purpose of temperature change is to ensure that the temperature field changes uniformly and the temperature fluctuations are minimal.
1.2.3. Apply broadband compression balance temperature control system to achieve fast temperature control through fast convergence PID adaptive algorithm
Speed control.
By utilizing a temperature regulating chamber, a static pressure chamber, and a forced air duct system with centrifugal blades, sufficient exchange of cold and hot air is ensured
Replace and evenly supply air through the top orifice plate to each space in the working room (experimental area) to reach the desired temperature
Uniformity; To achieve rapid temperature convergence, our company has independently developed a dedicated PID that is suitable for our company
Adaptive algorithm, which continuously adjusts the control based on temperature conditions during the control process to achieve fast sword retraction,
The control objective is to achieve low temperature overshoot and high stability.
1.2.4 Implement remote visual control.
The device is equipped with a human-machine management interface and a touch mode automation control system to achieve automatic control; Simultaneously through
The RS485 communication interface enables connection with remote computers, enabling network management and remote monitoring. The entire system passes through
Graphic interface, simple and fast control and management, automatic fault prompts, graphical prompts for energy-saving faults and proposed solutions
Method: Guide users to quickly troubleshoot.
2. Performance indicators and system composition of the comprehensive environmental cabin for the whole vehicle drum
Equipment usage
The heavy-duty hub environmental cabin is equipped with an environmental temperature simulation system, an environmental humidity simulation system, and a circulation system
Composed of wind system, fresh air system, sunlight simulation system, and exhaust emission system, mainly
For vehicle power performance, economic performance testing, air conditioning performance testing, thermal performance testing, etc
Provide environmental conditions.
Product Name
Vehicle hub integrated environmental cabin
model
GC-ZCHJC-887000D
Sample limitations
This testing equipment prohibits the testing of samples containing flammable, explosive, and volatile substances; Storage corrosion
Testing of sexual substance samples, testing of stored organisms, testing of stored samples of strong electromagnetic emission sources
Testing and storage
Volume, weight, and size
Vehicle information
Serial number
Vehicle parameters
parameter
one
Maximum external dimensions (length x width x height) (mm)
10000×2500×4200
two
Maximum curb weight of the vehicle (kg)
thirty-eight thousand
three
Maximum rated power of engine (kw)
522(700HP)
four
Maximum engine displacement (L)
fifteen
Nominal internal volume
887.4m3
Effective size of inner box
18000 (L) x 8500 (W) x 5800 (H) mm (depth x width x height) W x H x D (mm)
Effective size of outer box
26000 (L) x 8800 (W) x 10400 (H) mm (depth x width x height) W x H x D (mm)
External transition between warehouse bodies
1500mm×1500mm×2500mm
The vehicle entrance and exit doors are electrically operated swing doors
The minimum size is 4000mm (W) × 4500mm (H), with a thickness of ≥ 150mm,
Two observation windows, minimum size: 400mm (W) × 500mm (H), with heating function.
Warehouse personnel door and transition personnel door
The minimum size is 900mm (W) × 1900mm (H), with no less than one observation window,
Minimum size: 300mm (W) x 500mm (H), with heating function.
Equipment weight
About 38600 kg
Power, current, and power supply
Maximum installed power
Facing fan power: about 400kw; Refrigeration system power: approximately 300kw; Heating system power:
About 90kw; Humidification system power: approximately 80kw; Sunshine simulation power: about 150kw;
Other functional power: about 70kw; Equipment installation power: approximately 1090KW
Maximum current
The maximum current is about 1700A
Power supply conditions and sources
3 ¢ 380VAC ± 10%, 50Hz three-phase four wire+protective grounding
Voltage allowable fluctuation range: 10%
Allowable frequency fluctuation range: (50 ± 0.5) Hz
The grounding resistance of the protective grounding wire is less than 4 Ω
Require users to configure corresponding capacity air or power switches for the equipment at the installation site,
And this switch must independently control the use of this device
performance index
Functional requirements
1. (Air) indoor space cooling, heating, and dehumidification;
2. According to the temperature and humidity settings, the indoor space should reach the temperature required for the set test.
Test environment conditions
The value measured under the conditions of an ambient temperature of+25 ℃, relative humidity ≤ 85%, and no sample in the test chamber.
Meet the testing standards
test method
GB2423.1-2008/IEC6008-2-1-2007 Environmental testing for Electrical and Electronic Products
Part 2: Test Methods Test A: Low Temperature
2. GB/T 2423.2-2008 Environmental Testing for Electrical and Electronic Products Part 2:
Test Method Test B: High Temperature
3. GJB150.3A-2009 High temperature test method
4. GJB150.4A-2009 Low temperature test method
5. GB/T 10589-2008 Technical Conditions for Low Temperature Test Chamber
6. GB/T2423.3-2008 (IEC68-2-3) Test Ca: Constant Damp Heat Test Method
7. G/BT 2423.4-2008/IEC6008-2-30:2005 Test Db: Alternating Damp Heat Method
8. GB/T5170.18-2005 Calibration method for basic parameters of environmental testing equipment for electrical and electronic products
Temperature/humidity combined cycle testing equipment
9. GB/T10586-2006 Technical Conditions for Damp Heat Test Chamber
10. Requirements of GJB150-1986 and GJB150A-2009 standards, high temperature test
(GJB150.3-1986、11、GJB150.3A-2009)、 Low temperature test (GJB150.4-1986, GJB150.4A-2009), alternating 12, wet heat test (GJB150.9-1986, GJB150.9A-2009)
13. High temperature performance test of the whole machine (GB/T 3871.11-2005)
14. Thermal Balance Test of Engine Cooling System (JB/T 12847-2016)
15. Thermal balance test of the entire transmission system (Q/YT 542.5-2012)
16. Air conditioning test (GB/T 13877.2-2003)
17. Exhaust Smoke Measurement (GB/T 3871.13-2006)
18. Power output shaft power test (GB/T 3871.3-2006)
19. Other non-standard tests involve specific requirements for environmental conditions and determination of axle load output.
20. High temperature heat balance test and cabin air conditioning test for some harvesting machinery.
Temperature and humidity range
Temperature and humidity range
Temperature range:- 40~60℃
Humidity range: 10-98% RH (as shown in the figure)
control accuracy
Temperature resolution: 0.01 ℃
Temperature deviation: ±2℃;
Temperature uniformity: ≤ 2.0℃
Temperature fluctuation: ± 0.5 ℃
Humidity control accuracy
Humidity resolution: 0.1% RH
Humidity deviation:> ± 3.0% RH at 75% RH; ≤ ± 5.0% RH at 75% RH
Humidity uniformity: ≤ 3%RH
Humidity fluctuation: ± 2% RH
heating rate
Heating rate: -40 ℃ → 60 ℃, ≥ 0.4 ℃/min (with one 38 ton vehicle parked, static).
cooling rate
Cooling rate: 60 ℃ → -40 ℃, ≥ 0.4 ℃/min (with one 38 ton vehicle parked, static).
Equipment composition
Environmental cabin; Humidity control system; Temperature control system; Frontal cooling system; Fresh air compensation system; Exhaust emission system; Sunshine simulation system; Environmental cabin control system; monitoring system; Safety and alarm system; Hydrogen concentration monitoring system; Spray gun, steam generator; Simulation system; Rain and snow simulation system; Automatic throttle execution device; Defrosting test image recording system; Automated refrigerant calibration system; monitoring system; Control and data acquisition system; Auxiliary facilities: spare parts
Note: The above performance indicators are measured under the conditions of an ambient temperature of+25 ℃, a water temperature of 28 ℃, and a relative humidity of ≤ 85% RH; Temperature uniformity and temperature deviation measured under the condition of no sample
1. The equipment for the test project is not limited to the following test standards:
Serial number
Experimental project
environment condition
Vehicle operating conditions
Reference standards
one
Low temperature test
-40±2℃
static state
GJB 150.4A
two
High temperature test
60±2℃
static state
GJB 150.3A
three
Vehicle start-up test after cold start
-35℃±2
After driving in low gear for 500m, accelerate to the maximum speed (100km/h) within a maximum of 15min and then stop
GB/T 12535
four
Heating test
-30℃±2℃
60km/h
Maintain for 60 minutes
GB/T 12782
five
Heating test
-30℃±2℃
40km/h
60km/h
GOST 15150
six
Cold start test
-35℃±2℃
Start and keep running for 30 minutes
GB/T 12535
seven
Defrosting and defogging test
-20 ± 1 ℃ (defrosting)
-5 ± 1 ℃ (defogging)
40km/h
SAE J381
eight
Defrosting and defogging test
-18 ± 2 ℃ (defrosting)
-3 ± 1 ℃ (defogging)
neutral gear
50% rated speed
GB 11555
GB T 24552
nine
Thermal insulation and ventilation test
Temperature>35 ℃
Humidity range of 30% to 80%
80km/h
GB/T 12546
ten
Air conditioning test
(Refrigeration system)
normal atmospheric temperature:
Temperature 22 ℃
Humidity 70%
Wind speed 5m/s
High temperature:
Temperature 35 ℃
Humidity 40%~75%
Wind speed 5m/s
Light intensity 800W/m2
Idle speed -30 minutes
40km/h-45min
60km/h-30min
100km/h-30min
QC T 685
eleven
Static inspection
<-30℃
static state
GB T 28958
twelve
Speedometer odometer calibration test
18~28℃
40 , 60km/h
GB/T 12548
thirteen
Vehicle thermal balance test
>40℃
Engine at full load
GB/T 12542
fourteen
Fuel consumption test
20~30℃
/
GB/T27840